Patients at average risk of colorectal cancer who have a normal colonoscopy do not need to repeat screening for 10 years. It is common for polyps to be removed and tested during a colonoscopy, but the amount and size of polyps removed will change the patient’s follow-up screening schedule. In two new publications from the U.S. Multisociety Task Force (MSTF) on Colorectal Cancer, experts provide a timeline for patients to be rechecked for colorectal cancer based on their initial colonoscopy as well as recommendations for physicians to apply the safest and most effective techniques to completely remove polyps.

Colorectal cancer, the second leading cause of cancer death in the U.S., is preventable when precancerous polyps are found and removed before they turn into cancer. Screening for average-risk patients is recommended to begin at age 50. The recommendation documents from the U.S. Multisociety Task Force — which is comprised of representatives of the American College of Gastroenterology, the American Gastroenterological Association and the American Society for Gastrointestinal Endoscopy — aim to improve colorectal cancer prevention and early detection.

Recommendations for Follow-Up After Colonoscopy and Polypectomy1

For this publication, the U.S. MSTF reviewed their 2012 recommendations2 and provide an updated schedule for follow-up colonoscopy following a patient’s initial high-quality exam:

Patient has no polyps Next colonoscopy in 10 years
Patient has no polyps <10mm Next colonoscopy in 7-10 years (instead of 5-10 years)
Patient has 3-4 polyps <10mm Next colonoscopy in 3-5 years (instead of 3 years)
Patient has more than 10 polyps Next colonoscopy in 1 year (instead of 3 years)
Patient has serrated polyps Review the document for complete recommendations
Patient has advanced polyps Next colonoscopy in 3 years

To review all MSTF recommendations for patient follow-up, review the full publication.

Recommendations for Endoscopic Removal of Colorectal Lesions3

In this publication, U.S. MSTF provides best practices for the endoscopic removal of precancerous colorectal polyps during colonoscopy, which is called a polypectomy.

Best practices for polyp assessment and description
MSTF recommends macroscopic characterization of a polyp, which provides information to facilitate the polyp’s histologic prediction, and optimal removal strategy.

Best practices for polyp removal
The primary aim of polypectomy is complete removal of the colorectal lesion, and the subsequent prevention of colorectal cancer. Overall, the vast majority of benign colorectal lesions can be safely and effectively removed using endoscopic removal techniques. When an endoscopist encounters a suspected benign colorectal polyp that he/she is not confident to completely remove, MSTF recommends referral to an endoscopist experienced in advanced polypectomy for subsequent evaluation and management in lieu of referral for surgery.

Patient has diminutive (≤ 5mm) and small (6-9mm) polyp(s) Recommend cold snare polypectomy
Patient has non-pedunculated (≥ 20mm) polyp(s) Recommend endoscopic mucosal resection
Recommend snare resection of all grossly visible tissue of a polyp in a single colonoscopy session and in the safest minimum number of pieces
Recommend against the use of ablative techniques on endoscopically visible residual tissue of a polyp
Recommend the use of adjuvant thermal ablation of the post-EMR margin where no endoscopically visible adenoma remains despite meticulous inspection
Patient has pedunculated polyp(s) Recommend prophylactic mechanical ligation of the stalk with a detachable loop or clips on pedunculated polyps with head ≥20mm or with stalk thickness ≥5mm to reduce immediate and delayed post-polypectomy bleeding

Best practices for surveillance
MSTF recommends intensive follow-up schedule in patients following piecemeal endoscopic mucosal resection (lesions ≥ 20 mm) with the first surveillance colonoscopy at 6 months, and the intervals to the next colonoscopy at 1 year, and then 3 years.

To review all MSTF recommendations on polyp removal, review the full publication.

Task force members
  • Joseph C. Anderson, MD, MHCDS, Dartmouth Geisel School of Medicine, Hanover, New Hampshire
  • Carol A. Burke, MD, Cleveland Clinic, Ohio
  • Jason A. Dominitz, MD, MHS, University of Washington Medicine, Seattle
  • Samir Gupta, MD, MSc, University of California San Diego
  • Tonya R. Kaltenbach, MD, MS, University of California San Francisco
  • David A. Lieberman, MD, Oregon Health and Science University, Portland
  • Douglas K. Rex, MD, Indiana University School of Medicine, Indianapolis
  • Douglas J. Robertson, MD, MPH, Dartmouth Geisel School of Medicine, Hanover, New Hampshire
  • Aasma Shaukat, MD, MPH, Minneapolis VA Health Care System, Minnesota
  • Sapna Syngal, MD, MPH, Dana-Farber Cancer Institute, Boston, Massachusetts

The U.S. MSTF recommendations are published jointly in Gastroenterology, The American Journal of Gastroenterology, and Gastrointestinal Endoscopy.


References

1. Gupta S., Lieberman, D.A., Anderson, J.C. et al. Recommendations for Follow-Up After Colonoscopy and Polypectomy: A Consensus Update by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology 2020. Epub ahead of print.
2. Lieberman, D.A., Rex, D.K., Winawer, S.J. et al. Guidelines for colonoscopy surveillance after screening and polypectomy: a consensus update by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology. 2012; 143: 844–857
3. Kaltenbach, T., Anderson, J.C., Burke, C.A. et al. Endoscopic Removal of Colorectal Lesions—Recommendations by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology 2020. Epub ahead of print.

Medical Device News Magazinehttps://infomeddnews.com
Medical Device News Magazine is a division of PTM Healthcare Marketing, Inc. Pauline T. Mayer is the managing editor.

Stay Connected

spot_img

Don't Miss

Kleiner Device Labs Receives FDA Market Clearance for KG2 Surge Flow-Thru Interbody System

The system maximizes total bone graft delivery volume, better distributes graft bilaterally into the intervertebral disc space, and streamlines the implant delivery, positioning, and grafting process for TLIF and PLIF spinal fusion procedures.

Matthew Cranfill New ExtriCARE USA Director Of Clinical Services

"Matt's impressive experience and skillset easily made him our top pick," said Peter Mason, President of ExtriCARE USA.

Shannon Lantzy MedCrypt New VP of Consulting

"I met Shannon at a healthcare-related event several years ago and was immediately impressed with her passion and drive to move healthcare into a digital future," said Mike Kijewski, CEO of MedCrypt.

Mark Foster Joins Xenocor BOD

Foster is a versatile and visionary C-Suite executive who brings 20 years of general management and leadership experience from both venture-backed growth-stage organizations and world-class medical device companies

Hinge Health Acquires the Most Advanced Computer Vision Technology for Tracking Human Motion

CEO Daniel Perez explained, “We won’t stop investing in technology to deliver the most patient-centered digital clinic that improves member experience and outcomes while reducing costs. wrnch allows us to take a giant leap forward in all respects.”

Dale W Wood Congratulates the Huma Team on Raising $130 Million

Major health and technology companies across the world have committed upwards of $130 million to Huma Therapeutics, the health-tech company backed by Dale Ventures.

Rhaeos Awarded $4 Million NIH SBIR Grant

Under the NIH SBIR grant, Rhaeos will leverage their existing wireless sensor hardware to provide additional quantitative flow data to the clinician, giving insight into this currently inaccessible and highly relevant shunt performance metric.

By using this website you agree to accept Medical Device News Magazine Privacy Policy