Saudi Arabia Ministry of Health and Masimo Announce Automation of National Neonatal CCHD Screening Process Using Masimo Technology

Fusion Marketplace Changes Healthcare Traveler Experience

Fusion Marketplace is a traveler-first driven platform giving healthcare professionals the power to make decisions in their careers that they haven't been able to in the past.

Veranex Announces Investment From Summit Partners to Form Comprehensive Concept-to-Commercialization Medtech Services Company

As the first phase in building this global entity, Veranex has acquired three complementary solution providers: Ximedica, Quartesian, and Boston Healthcare Associates. By bringing these companies together, Veranex combines the industry’s key pillars of design and engineering, regulatory, clinical, and market access into a single-source solution.

Recently at Arab Health 2019, the Saudi Arabia Ministry of Health (MOH) and Masimo (NASDAQ: MASI) jointly announced the implementation of an automation solution designed to streamline the process of critical congenital heart disease (CCHD) screening of newborns using Masimo SET®, the first automation of its kind worldwide. This latest phase in Saudi Arabia’s national CCHD screening program, which began in 2016 as part of the Vision 2030 plan addressing improvements in healthcare and other areas, automates the collection and storage of screening data, helping to make the process both more efficient and more accurate.

In 2016, Saudi Arabia implemented a mandatory CCHD screening program for all newborns using the Masimo Eve™ Newborn Screening Application on Radical-7® Pulse CO-Oximeters® with SET® Measure-through Motion and Low Perfusion™ pulse oximetry technology. Over 100 independent and objective studies have shown SET® to outperform other pulse oximetry technologies.1 Crucially for newborn health, studies – including the largest CCHD screening study to date – have shown that SET® combined with clinical assessment significantly improved CCHD screening sensitivity.2-3 With its ability to accurately measure through motion and low perfusion, alongside its performance in outcome studies, SET® stands out as the most proven and established choice of pulse oximetry technology for clinicians and policy makers hoping to implement CCHD screening processes. Since the program began in 2016, more than 600,000 Saudi Arabian newborns have been screened using SET®, Radical-7, and Eve.

In 2018, Eve on Rad-97™ Pulse CO-Oximeters was added to the program. Masimo SET®, coupled with Eve to streamline the screening process, and now with Rad-97 and automated data collection and aggregation, provides a powerful and the only automated CCHD solution of its kind available worldwide. Last year alone 72 newborns were referred for CHD diagnosis and heart surgery to save their lives, as a result of positive screening results. The screenings are carried out at 200 medical centers operated by the MOH, with a further 170 private hospitals adopting the screening process in late 2018. By 2020, it is estimated that 550,000 newborns annually will be screened in Saudi Arabia.

Dr. Fahad A. Al Aql, advisor to the MOH responsible for implementing the CCHD screening program, commented, “We are thrilled to be able to announce that in 2018 alone, widespread use of our national CCHD screening protocol, facilitated by Masimo technology, caught 72 instances of CHD that might otherwise have gone undetected. Now, in this next phase, which we plan to implement nationwide by February, we are augmenting our screening program with additional technology – making it the only automated solution that uses Rad-97 and Eve – that we believe will make the process faster, easier for clinicians to perform, and less prone to error. Patient identification can be quickly accomplished through barcode wristband scanning, and the results, calculated by Eve, will be collected and uploaded to central EMRs automatically, without the need for manual transcription. More efficient, more accurate healthcare is a cornerstone of Vision 2030. With the support of His Excellency the Minister of Health, Dr. Tawfiq Al Rabiah, we are looking forward to continuing to advance the forefront of healthcare in Saudi Arabia with this implementation.”

Eve, available on Radical-7 and Rad-97, combines the power of Masimo SET® pulse oximetry with an automated pre- to post-ductal synchronization algorithm designed to reduce calculation errors during CCHD screening. In addition, Eve simplifies the CCHD screening process by providing visual instructions, animations, and a detailed, easy-to-interpret display of screening results. Saudi Arabia’s automation solution uses Masimo Iris Gateway™ to record and transmit screening results, labeled with unique patient identifiers for both mother and newborn, from Rad-97 and Radical-7 devices to hospital and national electronic medical record (EMR) systems, for efficient, accurate electronic charting and data aggregation in a unified, central health repository.

CCHD affects approximately 2.5 to 3 newborns per 1000 live births4 and requires intervention soon after birth to prevent significant morbidity or mortality; later detection in infants also increases the risk of brain damage.5 In a study of 39,821 infants, CCHD screening sensitivity increased from 63% with physical exam alone to 83% with physical exam and Masimo SET® pulse oximetry.2 In a study of 122,738 infants – the largest CCHD screening study to date – CCHD screening sensitivity increased from 77% to 93% with the combined use of Masimo SET® and clinical assessment.3


References

1. Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at http://www.masimo.com. Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
2. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
3. Zhao et al. Pulse oximetry with clinical assessment to screen for congenital heart disease in neonates in China: a prospective study. Lancet. 2014 Aug 30;384(9945):747-54.
4. Hoffman JL et al. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39(12):1890-1900.
5. 2011 Legislative Report; State of Maryland, Department of Health and Mental Hygiene, State Advisory Council on Hereditary and Congenital Disorders. Recommendations on Implementation of Screening for Critical Congenital Heart Disease in Newborns. Page 7.
6. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
7. Taenzer AH et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010:112(2):282-287.
8. Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
9. McGrath SP et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety. 2016 Jul;42(7):293-302.
10.

Estimate: Masimo data on file.

11.

http://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview.

spot_img

DON'T MISS

Hyperfine Adds Medtech Leader and Visionary Scott Huennekens as Executive Chairman

Mr. Huennekens’ public boards include Chairman of Acutus Medical (IPO August 2020); Chairman of Envista (IPO September 2019); and board member of Nuvasive. He also serves as a board member and past Chairman of the Medical Device Manufacturer’s Association (MDMA).

One Drop Reports Carrie Siragusa, CPA Appointed VP of Commercial Strategy, Biosensor

Formerly Head of Innovation and Diabetes Portfolio at Sanofi, Siragusa will be part of a team bringing a multi-analyte dermal sensor (biosensor) with continuous health sensing capabilities to market with a mission to provide broader access to continuous glucose monitoring.

Barbara Moorhouse Appointed as Medica Non-Executive Director

Barbara has extensive business and management experience in the private, public, and regulated sectors.

Subscribe to Medical Device News Magazine here.

Related Articles