Elixir Medical Announces Outstanding 12-Month Data for DynamX Coronary Bioadaptor System, Demonstrating No Target Vessel Revascularization, No Thrombosis and Positive Adaptive Remodeling of the Artery

Elixir Medical, a developer of innovative, drug-eluting cardiovascular devices, today announced outstanding 12-month data for the DynamX™ Coronary Bioadaptor System, the first coronary artery implant that adapts to vessel physiology.

Elixir Medical notes the tesults will be presented live tomorrow at 14:12 CEST on the Main Arena channel of the PCR e-Course as part of the Late-Breaking Trials session by Stefan Verheye, MD, PhD, co-principal investigator and senior interventional cardiologist at the Antwerp Cardiovascular Centre/ZNA Middleheim, Belgium.

Twelve-month results for the DynamX Bioadaptor demonstrate:

  • No target vessel revascularization
  • No device thrombosis
  • Vessel and implant expansion (3% and 5% increase in mean area, respectively) and no loss of mean lumen area, demonstrating positive adaptive remodeling and the device’s ability to preserve blood flow over time
  • Mean acute gain of 1.63mm (±0.34), demonstrating radial strength
  • In-device mean late lumen loss of only 0.12mm (±0.18), demonstrating the ability of the device and drug coating to inhibit disease progression

“Coronary arteries naturally have the ability to expand with disease progression in order to maintain blood flow to the heart,” said Antonio Colombo, MD, co-principal investigator and director, Cardiac Catheterization Laboratory, Columbus Hospital, Milan and Coordinators Cardiac Catheterization Laboratories GVM Group, Care and Research, Lugo (RA), Italy. “Drug-eluting stents (DES) cage the coronary arteries and hinder this physiological response. DynamX is the first metallic coronary artery implant to demonstrate positive adaptive remodeling of the vessel, enabling it to expand to accommodate disease progression. This may improve longer-term clinical outcomes.”

“The innovative DynamX Bioadaptor design was shown to match current drug-eluting stents (DES) in acute performance while offering the promise to improve upon the high adverse event rates that continue beyond year one with DES,” said Dr. Verheye. “In all measures, including clinical, QCA, IVUS, OCT, the bioadaptor demonstrated excellent performance and safety.”

The DynamX Bioadaptor is the only metallic drug-eluting coronary artery device designed to open and support the artery during healing, like a stent, while uniquely accommodating the vessel’s ability to grow in response to disease progression, which current DES cannot do.

The bioadaptor is designed to address the two to three percent adverse event rate that occurs with drug-eluting stents (DES) each year without plateau.1,2,3 The rigid design of DES constrains, or “cages,” natural artery movement, which has been associated with major adverse cardiac events (MACE).4 Clinical studies have shown that DES prevents positive adaptive remodeling,5 inhibits vessel compliance and dilation in response to the body’s changing blood flow needs,6,7 and causes vessel straightening.8

“While DES do an efficient job supporting the coronary artery, they permanently cage the vessel and show an adverse event rate that continues to build year-over-year without end. Physicians and their patients deserve a technology that treats coronary artery disease without making this compromise,” said Elixir Medical CEO Motasim Sirhan. “Elixir’s DynamX Bioadaptor stands as the only technology that has solved this conundrum. By creating a coronary artery device that restores the normal function of the artery, we expect to demonstrate safety and efficacy with a reduction in clinical events.”

The multi-center, single-arm, mechanistic clinical study enrolled 50 patients treated at six centers in Europe to evaluate the safety and performance of the device in de novo native coronary arteries. Primary endpoints included Target Lesion Failure (TLF), as well as QCA, IVUS and OCT measures.

The DynamX Bioadaptor is a metal implant coated in a drug-eluting bioresorbable polymer that initially supports the coronary artery during healing with radial strength, similar to DES. Over six months, the polymer coating dissolves, freeing couplers – or “uncaging elements” – on the rings to move with the natural expansion and contraction of the artery. This has been shown to (a) maintain the ability for positive adaptive remodeling, (b) restore vessel function, and (c) allow for the vessel’s return towards baseline angulation.

Prof. Verheye’s presentation will also be available on-demand following the Late Breaking Trial session at PCR Online.

Hot this week

Cartessa Aesthetics Partners with Classys to Bring EVERESSE to the U.S. Market

Classys, which is listed on the KOSDAQ, is one of South Korea's most distinguished aesthetic technology manufacturers, with devices distributed in 80+ markets globally. This partnership marks Classys's official entry into the American marketplace, with Cartessa Aesthetics as the exclusive distributor for EVERESSE, launched under the Volnewmer brand in current global markets.

Stryker Launches Next-Generation of SurgiCount+

Now integrated with Stryker's Triton technology, SurgiCount+ addresses two key challenges: retained surgical sponges and blood loss assessment. Integrating these previously separate digital solutions provides the added benefit of a more efficient, streamlined workflow for hospitals notes Stryker.

Nevro Receives CE Mark In Europe for It’s HFX iQ™ Spinal Cord Stimulation System

Nevro notes HFX iQ is the first and only SCS system with artificial intelligence (AI) technology that combines high-frequency (10 kHz) therapy built on landmark evidence that uses ongoing cloud data insights to deliver personalized pain relief

Recor Medical Reports: CMS Grants Distinct TPT Device Code and Category to Recor Medical for Ultrasound Renal Denervation

The approval of TPT offers incremental reimbursement payments for outpatient procedures performed with ultrasound renal denervation for Medicare fee-for-service beneficiaries. It becomes effective January 1, 2025, and is expected to remain effective for up to three years notes Recor Medical.

Jupiter Endovascular Reports | 1st U.S. Patient Treated with Jupiter Shape-shifting Thrombectomy Device

“Navigation challenges during endovascular procedures are often underappreciated and have led to under-adoption of life-saving procedures, such as pulmonary embolectomy. We have purpose-built our Endoportal Control technology to solve these issues and make important endovascular procedures accessible to more clinicians and their patients who can benefit from them,” said Carl J. St. Bernard, Jupiter Endovascular CEO. “This first case in the U.S. could not have gone better, and appears to validate the safety and performance we are seeing in our currently-enrolling European SPIRARE I study.”
Exit mobile version