No Carolina / NY / Florida
Ph: 561.316.3330

No Carolina | NY | Florida

Hip Innovation Technology Presents Data Demonstrating the Potential Utility of its Novel Hip Replacement System in Addressing Instability Following Total Hip Arthroplasty

Editor: What To Know

  • Unlike existing total hip replacement systems, the ball is placed on a trunnion within the acetabular cup instead of the femoral stem, and the polyethylene liner is attached to a femoral cup, which then attaches to the femoral stem, as opposed to the polyethylene liner being attached to the acetabular cup.
  • Hip Innovation Technology, LLC (HIT), a medical device company developing innovative orthopedic device solutions to advance the quality of life and quality of care for patients, announces the presentation of data demonstrating the potential utility of its novel Reverse Hip Replacement System (Reverse HRS) in addressing instability following total hip arthroplasty (THA, also referred to as total hip replacement).
  • In a poster presentation at the annual meeting of the Canadian Orthopaedic Association (COA), researchers reported Phase 1 data showing radiographic stability, as assessed by radio-stereometric analysis (RSA, a state-of-the-art x-ray technique used to evaluate device micro-motion and wear), in patients who underwent THA with the Reverse HRS.

Hip Innovation Technology, LLC (HIT), a medical device company developing innovative orthopedic device solutions to advance the quality of life and quality of care for patients, announces the presentation of data demonstrating the potential utility of its novel Reverse Hip Replacement System (Reverse HRS) in addressing instability following total hip arthroplasty (THA, also referred to as total hip replacement).

In a poster presentation at the annual meeting of the Canadian Orthopaedic Association (COA), researchers reported Phase 1 data showing radiographic stability, as assessed by radio-stereometric analysis (RSA, a state-of-the-art x-ray technique used to evaluate device micro-motion and wear), in patients who underwent THA with the Reverse HRS. The results suggest a low risk of aseptic loosening of the Reverse HRS, and a high likelihood of long-term implant fixation.

“Instability following total hip arthroplasty is a common mode of failure,” commented lead investigator Thomas Turgeon, MD, who is Director of Arthroplasty Research, Concordia Hip and Knee Institute and Board Member of the Orthopaedic Innovation Centre. “The Reverse Hip Replacement System is designed to increase stability at the extremes of motion, and to offer a potentially more forgiving implant positioning without reducing range of motion. The clinical outcome metrics we have observed thus far are consistent with well-functioning hip replacement, and support the stability of this novel implant device.”

Dr. Turgeon and colleagues reported findings from 22 patients (11 female, 11 male; mean age at surgery: 70.6 ± 3.5 years) implanted with the Reverse HRS. The mean 24-month acetabular migration in these patients was 0.09 ± 0.15mm (p=0.005), which compared favorably to the maximum acceptable migration of 0.2mm. Similarly, the mean 24-month femoral migration was 0.002 ± 0.19mm (p<0.001), compared to the maximal acceptable migration of 0.5mm. At 24 months post-THA, the Reverse HRS was also associated with significant improvements in patient-reported outcome measures including the hip disability and osteoarthritis outcome score (HOOS), Oxford Hip Score (OHS), Harris Hip Score (HHS), and the 36-item short-form survey (SF-36) physical score (p<0.001 for all).

“The results from this ongoing RSA assessment trial bolster the clinical rationale for the Reverse HRS and its unique implant design,” said George Diamantoni, Hip Innovation Technology’s Co-Founder and Chief Executive Officer. “The findings further validate and strengthen the importance for our soon to launch FDA approved IDE pivotal trial, which will evaluate the effectiveness and safety of the Reverse HRS in subjects undergoing primary THA. We believe the potential benefits of the Reverse HRS include hip stability at extended ranges of motion, reduced risk of device dislocation, and greater latitude for placement of hip components.”

About the Reverse HRS: The Reverse HRS is a Metal-on-Polyethylene reverse geometry hip prosthesis designed to improve stability at extended ranges of motion and reduce the risk of dislocation. Like most conventional systems, the Reverse HRS consists of a femoral stem, an acetabular cup and a cobalt-chrome ball that articulates within a polyethylene liner. Unlike existing total hip replacement systems, the ball is placed on a trunnion within the acetabular cup instead of the femoral stem, and the polyethylene liner is attached to a femoral cup, which then attaches to the femoral stem, as opposed to the polyethylene liner being attached to the acetabular cup.

Medical Device News Magazinehttps://infomeddnews.com
Medical Device News Magazine provides breaking medical device / biotechnology news. Our subscribers include medical specialists, device industry executives, investors, and other allied health professionals, as well as patients who are interested in researching various medical devices. We hope you find value in our easy-to-read publication and its overall objectives! Medical Device News Magazine is a division of PTM Healthcare Marketing, Inc. Pauline T. Mayer is the managing editor.

Recent News

CV Societies Propel Plans Forward for a New Board of Cardiovascular Medicine

“The open comment period is the time for cardiovascular physicians, allies in other medical specialties, patients, and others to make their voices heard on why an independent CV Board is the best path for cardiologists to stay up-to-date on best practices and evidence-based care, ensuring patients receive the best possible care,” said Jeffrey Kuvin, MD, president of the proposed Board’s new Board of Directors. “The field of cardiovascular medicine has evolved dramatically over the past few decades; now is the right time to develop an independent cardiovascular Board.”

Hyundai Bioscience Announces Clinical Development Plan for Niclosamide-based Metabolic Anticancer Drug Targeting P53 Mutation Cancer

Sang-ki Oh, CEO of Hyundai Bioscience, stated, "Niclosamide-based metabolic anticancer drug candidate will be the first P53-targeting anticancer treatment that selectively kills p53 mutated cancer cells," and added, "Through our subsidiary ADM Korea, we plan to conduct clinical trials targeting cancer patients with intractable cancer caused by p53 mutations, which will be the first step of clinical development on niclosamide-based anticancer agent pipeline."

Sedana Medical Completes Patient Recruitment for INSPiRE-ICU 1 Clinical Trial in the US

Peter Sackey further elaborated: "Once the 30-day follow-up of all patients is complete, we will enter into an intense phase of final monitoring, data cleaning and transfer to our statistician team for analysis. In parallel, the long-term outcomes at 3 and 6 months will be collected centrally by the Critical Illness, Brain Dysfunction, and Survivorship team at Vanderbilt Medical Center. With this parallel approach, we expect topline results in the autumn of this year and a swift regulatory submission in Q1, 2025".

Health / Lifestyle

Articles of Interest

Stay Connected

spot_img

About Medical Device News Magazine

About Medical Device News Magazine. A digital publication founded in 2008 located in the United States. The publication is one of the industry’s leading sources of medical device and biotech industry updates. Medical Device News Magazine is easily accessible 24/7/365 and is a fast 1, 2, 3 easy read! Our purpose is...

By using this website you agree to accept Medical Device News Magazine Privacy Policy