On the Masimo SET® Pulse Oximetry, today Masimo announced the results of a prospective study published in the International Journal of Neonatal Screening in which researchers in Marrakesh, Morocco, conducted the first Moroccan study on critical congenital heart disease (CCHD) screening for newborns using Masimo SET® pulse oximetry.1 The authors concluded that “Our results encourage us to strengthen screening for CCHD by adding pulse oximetry to the routine newborn screening panel.”

Dr. Slitine and colleagues sought to improve early detection of CCHD in Morocco by studying the feasibility of implementing CCHD screening using pulse oximetry. From March 2019 to January 2020, 8,013 asymptomatic newborns at Mother and Child Hospital (part of the Mohammed VI University Hospital of Marrakesh), who were “normal” according to neonatal examination using the current standard, were screened for CCHD in accordance with American Academy of Pediatrics (AAP) guidelines, including pre- and post-ductal oxygen saturation measurement, using Masimo Rad-97® and Radical-7® Pulse CO-Oximeters® with Masimo SET® pulse oximetry sensors.

The researchers found that, of the 8,013 infants screened, 7,998 newborns had a negative screen (99.82%) and 15 newborns were screen positive (0.18%). Of those 15, five were later diagnosed with CCHD and five with non-critical CHD; five were false positives (three of which had other underlying conditions). Of the 7,998 infants who passed, there was one false negative, an infant who was later diagnosed, at 2 months of age, with coarctation of the aorta.

The researchers noted that the screening test was “easy, simple, reliable, reproducible, acceptable, discriminating, well-accepted by parents and caregivers, and did not involve parental anxiety.” They also noted that “Pulse oximetry has a good specificity and sensitivity and thereby fulfills the criteria for screening. Additionally, most of the data in the literature suggest a favorable cost-effectiveness of this technique.”

The authors concluded, “Screening for CCHD is a reliable method for the early detection of critical congenital heart disease and even non-cardiac conditions. We think that it will have positive repercussions on infant mortality and morbidity in Morocco. It is an optimal test and it adapts perfectly to our context. We hope to implement it locally and nationally, as consistent with international best practice for newborn screening, to allow for timely detection of the infants born with CCHD in Morocco.”

Although the researchers at times use the term pulse oximetry generally, the specific pulse oximetry technology used in this study, as noted, was Masimo SET®. To date, six other large published CCHD screening studies,2-7 as well as additional, smaller studies,8-9 have used Masimo SET®. Cumulatively, the large studies represent 284,800 infants, which includes the largest CCHD study to date, of 122,738 newborns.2 All of these CCHD studies with Masimo SET® pulse oximetry showed improved screening sensitivity with the use of Masimo SET® alongside clinical assessment when compared to routine physical exam alone. With its ability to accurately measure through motion and low perfusion, alongside its performance in outcome studies, Masimo SET® stands out as the established choice of pulse oximetry technology for clinicians and policy makers hoping to implement CCHD screening processes.10


References

  1. Slitine N, Bennaoui F, Sable C, Martin G, Hom L, Fadel A, Moussaoui S, Inajjarne N, Boumzebra D, Mouaffak Y, Younous S, Boukhanni L, Maoulainine F. Pulse Oximetry and Congenital Heart Disease Screening: Results of the First Pilot Study in Morocco. Int J Neonatal Screen 6(53). 30 June 2020.
  2. Zhao et al. Pulse oximetry with clinical assessment to screen for congenital heart disease in neonates in China: a prospective study. Lancet. 2014 Aug 30;384(9945):747-54.
  3. de-Wahl Granelli A et al. Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39,821 newborns. BMJ. 2009;Jan 8;338.
  4. Ewer AK et al. Pulse Oximetry Screening for Congenital Heart Defects in Newborn Infants (Pulseox): A Test Accuracy Study. Lancet. 2011 Aug 27;378(9793):785-94.
  5. de-Wahl Granelli A et al. Noninvasive Peripheral Perfusion Index as a Possible Tool for Screening for Critical Left Heart Obstruction. Acta Paediatr 2007; 96(10): 1455-9.
  6. Meberg A et al. First Day of Life Pulse Oximetry Screening to Detect Congenital Heart Defects. J Pediatr 2008; 152:761-5.
  7. Schena F et al. Perfusion Index and Pulse Oximetry Screening for Congenital Heart Defects. J Pediatr. 2017 Apr;183:74-79.
  8. Hamilçıkan S, Can E. Critical Congenital Heart Disease Screening With a Pulse Oximetry in Neonates. J Perinat Med. 2018 Feb 23;46(2):203-207.
  9. Jawin V et al. Beyond Critical Congenital Heart Disease: Newborn Screening Using Pulse Oximetry for Neonatal Sepsis and Respiratory Diseases in a Middle-Income Country. PLoS One. 2015; 10(9): e0137580.
  10. Published clinical studies on pulse oximetry and the benefits of Masimo SET® can be found on our website at https://www.masimo.com. Comparative studies include independent and objective studies which are comprised of abstracts presented at scientific meetings and peer-reviewed journal articles.
  11. Castillo A et al. Prevention of Retinopathy of Prematurity in Preterm Infants through Changes in Clinical Practice and SpO2 Technology. Acta Paediatr. 2011 Feb;100(2):188-92.
  12. Taenzer AH et al. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010:112(2):282-287.
  13. Taenzer A et al. Postoperative Monitoring – The Dartmouth Experience. Anesthesia Patient Safety Foundation Newsletter. Spring-Summer 2012.
  14. McGrath SP et al. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation. The Joint Commission Journal on Quality and Patient Safety. 2016 Jul;42(7):293-302.
  15. Estimate: Masimo data on file.
  16. https://health.usnews.com/health-care/best-hospitals/articles/best-hospitals-honor-roll-and-overview.
SourceMasimo

Hot this week

Avery Dennison Medical Introduces Ipdated SilFoam Lite: Sustainability, MDR Certification & Performance Improvements

The newly enhanced SilFoam Lite delivers superior efficiency and reliability, bringing improved fluid handling capabilities and improved tack. These improvements make the product ideal for customers seeking quality, high-performance solutions in wound care notes Avery Dennison Medical.

Voluntary Recall Notifying Medtronic Insulin Pump Users of Potential Risks of Shortened Pump Battery Life

Medtronic plc voluntarily issued a field action starting on July 31, 2024, notifying global customers of its MiniMed™ 600 series or 700 series insulin pumps to follow their pump's built-in alerts and alarms for battery status and to contact Medtronic if they observe changes in the battery life of their pump

Medtronic Expands AiBLE Spine Surgery Ecosystem with New Technologies and Siemens Healthineers Partnership

New advancements in the AiBLE Spine Surgery ecosystem build upon the company's commitment to procedural innovation and execution

Axlab, Danish Medtech Pioneer, expands to US with Advanced Robotic Tissue Sectioning for Pathology Laboratories

Kris Rokke, National Sales Director for Axlab in the US. "My team and I are extremely excited and honored about this unique opportunity to also offer this advanced technology to labs across the US and thus contribute to the pathology labs of tomorrow."

Spartan Medical Broadens Single-Use Sterile Instrument Portfolio to Improve Outcomes, Increase Efficiency, and Generate Cost Savings

Spartan Medical products portfolio of single-use, sterile med tech includes micro and minor surgical convenience kits, kerrison rongeurs, spinal and general surgical retractors, dural repair kits, synthetic biologics, and a wide range of orthopedic pre-sterilized implants and devices.