ACR Recommendations for the use of Chest Radiography and Computed Tomography (CT) for Suspected COVID-19 Infection

 

To date, most of the radiologic data comes from China. Some studies suggest that chest CT in particular may be positive in the setting of a negative test. We want to emphasize that knowledge of this new condition is rapidly evolving, and not all of the published and publicly available information is complete or up-to-date.

Key goals for the U.S. health care system in response to the COVID-19 outbreak are to reduce morbidity and mortality, minimize disease transmission, protect health care personnel, and preserve health care system functioning.

The ACR believes that the following factors should be considered regarding the use of imaging for suspected or known COVID-19 infection:

  • The Centers for Disease Control (CDC) does not currently recommend CXR or CT to diagnose COVID-19. Viral testing remains the only specific method of diagnosis. Confirmation with the viral test is required, even if radiologic findings are suggestive of COVID-19 on CXR or CT.
  • For the initial diagnostic testing for suspected COVID-19 infection, the CDC recommends collecting and testing specimens from the upper respiratory tract (nasopharyngeal AND oropharyngeal swabs) or from the lower respiratory tract when available for viral testing.
  • Generally, the findings on chest imaging in COVID-19 are not specific, and overlap with other infections, including influenza, H1N1, SARS and MERS. Being in the midst of the current flu season with a much higher prevalence of influenza in the U.S. than COVID-19, further limits the specificity of CT.

Additionally, there are issues related to infection control in health care facilities, including the use of imaging equipment:

  • Primary care and other medical providers are attempting to limit visits of patients with suspected influenza or COVID-19 to health care facilities, to minimize the risk of spreading infection. The CDC has also asked that patients and visitors to health care facilities be screened for symptoms of acute respiratory illness, be asked to wear a surgical mask and be evaluated in a private room with the door closed.
  • In addition to environmental cleaning and decontamination of rooms occupied by a patient with suspected or known COVID-19 infection by thorough cleaning of surfaces by someone wearing proper protective equipment, air-flow within fixed radiography or CT scanner rooms should be considered before imaging the next patient. Ventilation is an important consideration for the control of airborne transmission in health care facilities . Depending on the air exchange rates, rooms may need to be unavailable for approximately 1 hour after imaging infected patients; air circulation rooms can be tested.
  • These measures to eliminate contamination for subsequent patients may reduce access to imaging suites, leading potentially to substantial problems for patient care.

Based on these concerns, the ACR recommends:

  • CT should not be used to screen for or as a first-line test to diagnose COVID-19
  • CT should be used sparingly and reserved for hospitalized, symptomatic patients with specific clinical indications for CT. Appropriate infection control procedures should be followed before scanning subsequent patients.
  • Facilities may consider deploying portable radiography units in ambulatory care facilities for use when CXRs are considered medically necessary. The surfaces of these machines can be easily cleaned, avoiding the need to bring patients into radiography rooms.
  • Radiologists should familiarize themselves with the CT appearance of COVID-19 infection in order to be able to identify findings consistent with infection in patients imaged for other reasons.

Recommended Resources:

Centers for Disease Control:

Radiologic articles and collections:

Hot this week

Recor Medical Reports: CMS Grants Distinct TPT Device Code and Category to Recor Medical for Ultrasound Renal Denervation

The approval of TPT offers incremental reimbursement payments for outpatient procedures performed with ultrasound renal denervation for Medicare fee-for-service beneficiaries. It becomes effective January 1, 2025, and is expected to remain effective for up to three years notes Recor Medical.

Jupiter Endovascular Reports | 1st U.S. Patient Treated with Jupiter Shape-shifting Thrombectomy Device

“Navigation challenges during endovascular procedures are often underappreciated and have led to under-adoption of life-saving procedures, such as pulmonary embolectomy. We have purpose-built our Endoportal Control technology to solve these issues and make important endovascular procedures accessible to more clinicians and their patients who can benefit from them,” said Carl J. St. Bernard, Jupiter Endovascular CEO. “This first case in the U.S. could not have gone better, and appears to validate the safety and performance we are seeing in our currently-enrolling European SPIRARE I study.”

Avery Dennison Medical Introduces Ipdated SilFoam Lite: Sustainability, MDR Certification & Performance Improvements

The newly enhanced SilFoam Lite delivers superior efficiency and reliability, bringing improved fluid handling capabilities and improved tack. These improvements make the product ideal for customers seeking quality, high-performance solutions in wound care notes Avery Dennison Medical.

Voluntary Recall Notifying Medtronic Insulin Pump Users of Potential Risks of Shortened Pump Battery Life

Medtronic plc voluntarily issued a field action starting on July 31, 2024, notifying global customers of its MiniMed™ 600 series or 700 series insulin pumps to follow their pump's built-in alerts and alarms for battery status and to contact Medtronic if they observe changes in the battery life of their pump

Medtronic Expands AiBLE Spine Surgery Ecosystem with New Technologies and Siemens Healthineers Partnership

New advancements in the AiBLE Spine Surgery ecosystem build upon the company's commitment to procedural innovation and execution