A Digital Publication for the Practicing Medical Specialist, Industry Executive & Investor

No Carolina / New York

Orthofix Medical Report: Full Two-Year Authoritative Data on the M6-C Artificial Cervical Disc Study Shows Significant Improvement in Neck and Arm Pain

Shows Significant Improvement in Pain, Function and Quality of Life Scores

Orthofix Medical reported today on the full two-year outcomes from its U.S. Investigational Device Exemption (IDE) study of the M6-C artificial cervical disc.

Dr. Jack Zigler, orthopedic spine surgeon at Texas Back Institute and an investigator in the study, presented the study results during the International Society for the Advancement of Spine Surgery (ISASS) annual meeting in Anaheim, California.

Orthofix Medical reports the data demonstrates that patients treated with the M6-C artificial cervical disc had significant improvements in neck and arm pain, function and quality of life scores. Additionally, these patients had a significant difference in the reduction of pain and opioid medications use when compared to anterior cervical discectomy and fusion (ACDF) patients. At 24 months, patients in the ACDF group who were still using pain medications had a seven times higher rate of opioid use than those in the M6-C disc group.

“The results from the M6-C artificial cervical disc IDE clinical study continue to validate the positive outcomes of cervical disc arthroplasty versus discectomy with fusion,” said Zigler. “A significant reduction in pain, the maintenance or improvement of neurological function, and the preservation of natural disc motion after 24 months were all meaningful clinical benefits the M6-C disc patients experienced when compared to the fusion control. Additionally, patients receiving the M6-C disc were able to significantly lower their use of NSAIDs – and more importantly – significantly lower their use of opioid medications.”

A prospective, non-randomized, concurrently controlled clinical trial, the M6-C IDE study was conducted at 23 sites in the United States with an average patient age of 44 years. The study evaluated the safety and effectiveness of the M6-C artificial cervical disc compared to ACDF for the treatment of single level symptomatic cervical radiculopathy with or without cord compression. The overall success rate for the protocol-specified primary endpoint for the M6-C disc patients was 86.8 percent at 24 months and 79.3 percent in the control group. This data statistically demonstrates that cervical disc replacement with the M6-C disc is not inferior to treatment with ACDF.

Secondary outcomes at 24 months include:

  • Patients who received the M6-C disc demonstrated statistically significant improvement in the Neck Disability Index as measured at week six and months three, six, 12 and 24.
  • Meaningful clinical improvement was seen in the following pain scores:
    • 91.2 percent of patients who received the M6-C disc reported an improvement in neck pain compared to 77.9 percent in patients who underwent the ACDF procedure.
    • 90.5 percent of the M6-C patients reported improvement in arm pain scores compared to 79.9 percent in ACDF patients.
  • Prior to surgery, 80.6 percent of the M6-C disc patients and 85.7 percent of the ACDF patients were taking some type of pain medication for the treatment of their cervical spine condition. At 24 months, the rate of M6-C patients who were still taking some type of pain medication dropped to 14.0 percent compared to 38.2 percent of the ACDF patients.
    • Of these, there was a seven times higher rate of opioid use with the ACDF patients than with patients who received the M6-C disc.
  • There was a statistically significant difference in the average mean surgery time – 74.5 minutes for patients receiving the M6-C disc versus 120.2 minutes for those patients having the ACDF procedure.
  • In addition, there was a statistically significant difference in the mean length of hospital stay – 0.61 days for the M6-C patients versus 1.10 days for ACDF patients.
  • Subsequent surgery at the treated level was needed in 4.8 percent of the ACDF patients compared to 1.9 percent of the M6-C disc patients.
  • There were no device migrations reported in the study.
  • Overall patients receiving the M6-C disc reported a 92-percent satisfaction rate with the surgery, and 93 percent said they would have the surgery again.
  • There were 3.8 percent serious adverse events related to the device or procedure in the M6-C disc group versus 6.1 percent in the ACDF group.

The M6-C disc received U.S. Food and Drug Administration (FDA) approval in February 2019 based on the results of this study.

“With the recent FDA approval of the M6-C artificial cervical disc, we are excited to be able to provide spine surgeons and their patients a new and innovative alternative to the ball-and-socket artificial disc designs currently available in the U.S.,” said Global President of Orthofix Spine Brad Niemann. “What makes the M6-C disc so unique is its physiologic single-piece design featuring an artificial nucleus and annulus that work together to mimic the biomechanical motion of a natural disc to include axial compression or shock absorption, which no other disc available in the U.S. has to offer.”

The M6-C artificial cervical disc is a next-generation intervertebral disc designed to restore physiologic motion to the spine and is indicated as an alternative to cervical fusion. The device is comprised of ultra-high molecular weight polyethylene fiber wrapped in a specific pattern, with multiple redundant layers that create a fiber matrix (artificial annulus). The fiber is then wound around a polycarbonate urethane polymer core creating an artificial nucleus. Like a natural disc, this unique construct allows for shock absorption at the implanted level, as well as provides a controlled range of motion when the spine transitions in its combined complex movements.

Orthofix is releasing the M6-C artificial cervical disc in 2019 through a controlled, limited market launch in the U.S. accompanied by an extensive training and education curriculum for surgeons.

The M6-C artificial cervical disc received CE Mark approval for distribution in the European Union and other international geographies in 2006; there have been more than 45,000 implants of the M6-C artificial cervical disc outside of the U.S. to date.

Medical Device News Magazinehttps://infomeddnews.com
Medical Device News Magazine provides breaking medical device / biotechnology news. Our subscribers include medical specialists, device industry executives, investors, and other allied health professionals, as well as patients who are interested in researching various medical devices. We hope you find value in our easy-to-read publication and its overall objectives! Medical Device News Magazine is a division of PTM Healthcare Marketing, Inc. Pauline T. Mayer is the managing editor.

More News!

Dr. Michael Newman, Indaptus’ Founder, Chief Scientific Officer, and lead author, commented, “The new data are consistent with our preclinical animal tumor model studies and provide evidence for our hypothesis that patented Decoy bacteria can activate a wide range of innate and adaptive human immune cells involved in fighting tumors.  This aligns with what we’ve observed in our ongoing Phase 1 clinical trial of Decoy20 – broad immune activation, as evidenced by transiently increased levels of many key cytokines and chemokines following single dose administration. These findings bolster our confidence in Decoy20's potential as a multifaceted immunotherapy.”
“We are excited to present the first look at the safety and clinical activity of ELVN-001, which we believe supports the potential for ELVN-001 to address the limitations of the available active-site TKIs,” said Helen Collins, M.D., Chief Medical Officer of Enliven. “Across a wide dose range, ELVN-001 demonstrated activity in a heavily pre-treated patient population that includes post-asciminib patients, with a preliminary safety profile consistent with its highly selective design. Not only did all evaluable patients have improved or stable BCR::ABL1 transcript levels, but, importantly, 89% of all patients enrolled remain on study. We believe the initial data demonstrate the potential clinical utility of ELVN-001 for all types of patients, including those that are earlier in the treatment paradigm.”