The new Roden ADA Kit expedites bioanalysis by removing the need for assay development and optimization across molecules to provide robust, reproducible, reliable data from nanoliter sample volumes. This is beneficial when ADA assessment is evaluated in preclinical animal models where sample volume may be limited.

CEUS Underutilization May Pose Greater Risk Than Rare Side Effects Associated With Use, Say Experts

Summation

  • Contrast enhanced ultrasound (CEUS) is underutilized in the United States, and reduced access to this noninvasive diagnostic imaging tool may pose a greater risk to patients than rare side effects associated with use, according to doctors who spoke today at the 37th International Bubble Conference in Chicago.
  • In addition, cardiac angiography presents a risk of death in 1/1,000 patients, and SPECT or MUGA imaging presents a risk of fatal malignancies in 1/1,000-1/10,000 patients.
  • The conference drew CEUS experts from North America, Europe, China and Brazil, and focused on advances in the use of “microbubble” ultrasound enhancing agents (UEAs) used routinely worldwide to diagnose heart and vascular disease, identify and characterize tumors, monitor chronic gastro-intestinal diseases, evaluate other serious medical conditions and monitor therapy.

Contrast enhanced ultrasound (CEUS) is underutilized in the United States, and reduced access to this noninvasive diagnostic imaging tool may pose a greater risk to patients than rare side effects associated with use, according to doctors who spoke today at the 37th International Bubble Conference in Chicago.

The conference drew CEUS experts from North America, Europe, China and Brazil, and focused on advances in the use of “microbubble” ultrasound enhancing agents (UEAs) used routinely worldwide to diagnose heart and vascular disease, identify and characterize tumors, monitor chronic gastro-intestinal diseases, evaluate other serious medical conditions and monitor therapy. UEAs do not contain dye, create no known risk of kidney damage or deposit of contrast media in the brain, and do not expose patients or hospital staff to ionizing radiation.

“CEUS is among the safest of contrast media available,” according to Dr. Strom, an Assistant Professor of Medicine at Harvard Medical School and Director of the Echocardiography Laboratory at Beth Israel Deaconess Medical Center in Boston. He noted that UEAs present a rare risk of a severe allergic reaction in 1/15,000 patients. By comparison, iodinated contrast agents used for CT present a risk of life threatening reactions in 1/500 to 1/5,000 patients. In addition, cardiac angiography presents a risk of death in 1/1,000 patients, and SPECT or MUGA imaging presents a risk of fatal malignancies in 1/1,000-1/10,000 patients.

To reduce UEA risk even further, Dr. Strom said “dilution of the agent is key.” He noted that vendors are not allowed to recommend UEA dilution because government regulations prohibit them from providing information that is not expressly contained in product labels approved by the FDA.

Dr. Strom suggested that clinical applications specialists may, however, refer customers to new professional guidelines recently published in Echo Research and Practice: “CEUS cardiac exam protocols: International Contrast Ultrasound Society (ICUS) recommendations.” These guidelines address dilution and other evidence-based options for optimal UEA administration.

Dr. Strom also stressed the importance of preparedness for rare adverse events, and recommended staff training and assessment, detailed planning for a local response including who is responsible for specific tasks, having allergy kits available and stocked, tracking any issues and debriefing afterward. He also recommended posting a safety placard and having an emergency pager that is always covered.

“Despite the rare risk of an adverse event associated with UEAs, patients face an even greater risk associated with non-use,” said Dr. Tom Porter, lead author of the ICUS guidelines. Dr. Porter is Chair of Cardiology and Professor of Internal Medicine at the University of Nebraska Medical Center in Omaha.

Dr. Strom said that up to 40% of patients receiving echocardiograms at his medical center receive a UEA. This produces vital diagnostic information and in studies has been associated with reduced need for downstream imaging and cardiac catheterizations. He also said that CEUS use has even been associated with a reduced length of hospital stay in some patients.

Research led by Dr. Strom also showed significant regional variation in use of UEAs and overall underutilization, resulting in varying standards of care across the country. According to Dr. Strom, the highest per capita use of UEAs is in Minnesota, whereas the lowest utilization is in Delaware.

UEAs are manufactured and sold by Bracco, Lantheus and GE Healthcare.

SonoVascular Enters Into Strategic Collaboration with Lantheus Holdings | for Use of Microbubbles in Combination with SonoThrombectomy™ System for Treatment of Venous Thromboembolism

"SonoVascular is honored to have the opportunity to partner with Lantheus, a leader in microbubble development," said Daniel Estay, Founder and Chief Executive Officer of SonoVascular. "Our SonoThrombectomy System, combined with Lantheus' microbubbles, is designed to provide a true, next-generation solution for the treatment of DVT and PE that overcomes the drawbacks associated with catheter-based thrombectomy and thrombolysis devices."

Anaut Announces Japanese Regulatory Approval of AI-Powered Surgical Visualization Tool, Eureka α

Eureka α utilizes state-of-the-art AI to analyze real-time video from laparoscopic and robotic surgery, enhancing surgeons' accuracy by highlighting the dissection planes characterized by connective tissue.

Discover Reeva FT: Revolutionizing Wound Covering for Healthcare Pros

Reeva FT is offered in a variety of sizes: 2x2 cm, 2x3 cm, 4x4 cm, 4x6 cm, 4x8 cm, and 10x15 cm. Reeva FT is confirmed by the FDA Tissue Reference Group to meet the criteria for regulation solely under Section 361 of the PHS Act as defined in 21 CFR Part 1271.
Medical Device News Magazinehttps://infomeddnews.com
Medical Device News Magazine provides breaking medical device / biotechnology news. Our subscribers include medical specialists, device industry executives, investors, and other allied health professionals, as well as patients who are interested in researching various medical devices. We hope you find value in our easy-to-read publication and its overall objectives! Medical Device News Magazine is a division of PTM Healthcare Marketing, Inc. Pauline T. Mayer is the managing editor.

By using this website you agree to accept Medical Device News Magazine Privacy Policy